| ype: |
PNOZ XV3.1P |
| Product version: |
2.2 |
| Approvals: |
CE, cULus Listed, TÜV, GOST, CCC |
| Application options: |
Safety gate monitor, Instantaneous E-STOP monitoring, Limit switch, Delayed E-STOP monitoring, Light beam device mon. Type 4, Light beam device mon. Type 2 with t/p, Light beam device mon. Type 2 w/o t/p |
| Operating modes: |
Single-channel, Automatic reset, Dual-channel, Detection of shorts across contacts, Monitored manual reset, without detection of shorts across contacts |
| PL EN ISO 13849-1 inst. contacts: |
e |
| PL EN ISO 13849-1 del. contacts <30s: |
d |
| PL EN ISO 13849-1 del. contacts >30s: |
c |
| SIL CL IEC 62061 inst. contacts: |
3 |
| SIL CL IEC 62061 del. contacts <30s: |
3 |
| SIL CL IEC 62061 del. contacts >30s: |
3 |
| Product standard: |
EN 60947-5-1 |
| Standards: |
EN 60204-1, EN 62061, EN 954-1, VDE 0113-1 |
| Supply voltage: |
24 - 240 V |
| Supply voltage type: |
AC/DC |
| Supply voltage range: |
24 - 240 V |
| Terminal style: |
Plug-in |
| Terminal type: |
Screw terminal |
| Cat. inst. saf. contacts: |
4 |
| Cat. del. saf. contacts < 30s: |
3 |
| Cat. del. saf. contacts > 30s: |
1 |
| Number of instantaneous safety contacts: |
3 |
| Number of delayed safety contacts: |
2 |
| Safety contact delay type: |
Delay-on de-energisation |
| Number of auxiliary contacts: |
1 |
| Selectable times: |
0,00 s, 0,50 s, 1,00 s, 10,00 s, 15,00 s, 2,00 s, 20,00 s, 25,00 s, 30,00 s, 4,00 s, 6,00 s, 8,00 s |
| Stop category: |
0/1 |
| Max. current at DC13 I (6 cycles/min): |
7.0 A |
| Max. current at AC15: |
5.0 A |
| Width dimension: |
90.0 mm |
| Height dimension: |
94.0 mm |
| Depth dimension: |
121.0 mm |
| Gross weight: |
570 g |
| Net weight: |
540 g |
| Ambient temperature: |
-10 - 55 °C |