| Function |
Preset Counter |
| Preset stages |
1stages |
| Rated supply voltage |
100 to 240 VAC 50/60 Hz |
| Operating voltage range |
85% to 110% of the rated power supply voltage |
| Power consumption |
Approx. 12 VA (at 100 VAC) |
| Counter (Count range) |
0~9999 |
| Counter (Max. counting speed) |
5 kHz (Minimum counting input signal width: 0.1 ms (ON/OFF ratio: 1:1)) |
| Counter (Input mode) |
Increment |
| Counter (Output modes) |
N |
| Counter (Reset system) |
External, manual and power reset |
| Input signal |
Count / Reset / CP1 / CP2 |
| Input method |
No-voltage input |
| No-voltage input (No-contact input) |
Short-circuit (ON) impedance: 1 kΩ
Residual voltage: 2 V max.
Open circuit impedance: 100 kΩ |
| No-voltage input (Contact input) |
Use a contact which can adequately switch 0.5 mA at 5 V. |
| Minimum input signal width |
External reset: 20 ms
Manual reset: 20 ms
Power reset: 500 ms |
| Control output (Contact output) |
- |
| Control output (Solid-state output) |
Output type: Transistor output (NPN open collector)
Switching capacity: 30 VDC max., 100 mA max. |
| Display method |
7-segment LED |
| Digits |
4digits |
| Character height |
Count value: 10 mm (Red)
Zero suppression: Not provided |
| Prescaling function |
Not provided |
| Key protection |
Not provided |
| Teaching function |
Not provided |
| Batch counting function |
Not provided |
| Communications |
Not provided |
| Memory backup |
Not provided () |
| Surrounding air temperature |
Operating: -10 to 55 ℃
Storage: -25 to 65 ℃ |
| Ambient humidity |
Operating: 35 to 85%
Storage: 35 to 85% |
| Insulation resistance |
100 MΩ min. (at 500 VDC)
Between current carrying terminals and exposed non-current carrying metal parts / Between control output terminals and operating circuit |
| Dielectric withstand voltage |
Between current carrying terminals and exposed non-current carrying metal parts:2000 VAC 50/60 Hz for 1 min
Between control output terminals and operating circuit:2000 VAC 50/60 Hz for 1 min |
| Impulse withstand voltage |
Between power terminals:6.0 kV
Between current carrying terminals and exposed non-current carrying metal parts:6.0 kV |
| Noise immunity |
Between power terminals:±2k V
Between input terminals:±500 V
Square-wave noise by noise simulator (Pulse width: 100 ns/1 µs, 1-ns rise) |
| Static immunity |
±8 kV (malfunction) |
| Vibration resistance (Destruction) |
10 to 55 Hz, 0.75-mm single amplitude each in 3 directions for 2 h |
| Vibration resistance (Malfunction) |
10 to 55 Hz, 0.5-mm single amplitude each in 3 directions for 10 min |
| Shock resistance (Destruction) |
300 m/s**2, 3 times each in 6 directions (3 axes) |
| Shock resistance (Malfunction) |
100 m/s**2, 3 times in each directions (3 axes) |
| Degree of protection |
Case front: IP40
Case rear: IP40
Terminal block: IP00 |
| Mounting method |
Flush mounting/Surface mounting |
| External connection method |
8-pinSocket |
| Case color |
Light gray (Munsell 5Y7/1) |
| Weight |
Approx. 110 g
|